IES-5000/5005/6000 Integrated Ethernet Switch Support Notes July 2008 Edition 3
IES-5000/5005/6000 Support Notes 9d. Click the Setup button in sub-step (1) of the VLAN to open the page relevant for sub-step (2) & (3): Sub
IES-5000/5005/6000 Support Notes 99 7-42 accept-all 7-43 accept-all 7-44 accept-all 7-45 accept-all 7-46 accept-all 7-47 accept-all 7-48 acc
IES-5000/5005/6000 Support Notes 10Sub-step (3): Join VLAN 500 to VDSL port 1. Sub-step (4): Check the final VLAN setup status, you should see t
IES-5000/5005/6000 Support Notes 11Sub-step (5): Set the default PVID/Priority for the VDSL Port1, click Apply to save the changes. All contents
IES-5000/5005/6000 Support Notes 123. Configure the MSC1000G. a. Click VLAN > VLAN b. Select VLAN 100 and click Modify, then set the port U
IES-5000/5005/6000 Support Notes 13d. Check the final VLAN setup status of the MSC1000G All contents copyright (c) 2008 ZyXEL Communications Cor
IES-5000/5005/6000 Support Notes 144. Use ACL rule to replace the VID / Priority for the PPPoE packets. [Note]: So far ACL-rule feature does not
IES-5000/5005/6000 Support Notes 15b. ACL-rule profile CLI syntax: (1). <rule> is for picking out the traffic by specific parameters, e.g.
IES-5000/5005/6000 Support Notes 16c. Set ACL-rules to pick out PPPoE traffic and replace its VID / Priority. (1) Create ACL profiles // ‘pppoe1
IES-5000/5005/6000 Support Notes 175. Use MVR to configure the IPTV setting on MSC1000G. a. Login: As in the step 4, use Telnet to login. b.
IES-5000/5005/6000 Support Notes 186. Configure the IGMP-Proxy and Static Query VLAN a. Login: We are using the WEB to configure again. b. Cli
IES-5000/5005/6000 Support Notes 1INDEX Application Notes...
IES-5000/5005/6000 Support Notes 19d. Check the Query VLAN status. All contents copyright (c) 2008 ZyXEL Communications Corporation.
IES-5000/5005/6000 Support Notes 207. Save configuration for the IPDSLAM. (1). Open Config Save, then click the Save button to save all your set
IES-5000/5005/6000 Support Notes 21Configure the ES-2024A: 1. System login. a. Connect to the ES-2024A via Internet browser. 192.168.1.1 is th
IES-5000/5005/6000 Support Notes 222. Configure VLANs. a. Click Advanced Application > VLAN, after enter the VLAN setting page, and then choos
IES-5000/5005/6000 Support Notes 23(2). VLAN 500 for VoIP. All contents copyright (c) 2008 ZyXEL Communications Corporation.
IES-5000/5005/6000 Support Notes 24(3). VLAN 700 for IPTV. All contents copyright (c) 2008 ZyXEL Communications Corporation.
IES-5000/5005/6000 Support Notes 25(4). Check final status of the VLAN settings. All contents copyright (c) 2008 ZyXEL Communications Corporation
IES-5000/5005/6000 Support Notes 26c. Set the default PVID for the relative ports in this scenario. (1). Click Advance Application > VLAN, the
IES-5000/5005/6000 Support Notes 27d. Set the default 802.1p Priority value for the respective ports in this scenario. (1). Click Basic Setting &
IES-5000/5005/6000 Support Notes 28e. Save all the settings for the ES-2024A. (1). Click Management > Maintenance, then choose the Config 1 in
IES-5000/5005/6000 Support Notes 2Application Notes Triple play Application (with VLC Line Card) The triple play service is a marketing term for
IES-5000/5005/6000 Support Notes 29Triple play Application (with ALC/SLC Line Card) On the IES-5000, you can use different channels (also known a
IES-5000/5005/6000 Support Notes 30In this network application, we will use an IES-5000, a ZyXEL ES-2024 VLAN-aware switch and Prestige 660R-61 CP
IES-5000/5005/6000 Support Notes 31Since we want to give the 0/33 VPI/VCI a higher priority, change the VCI/VPI priority in the Defval_CBR profile
IES-5000/5005/6000 Support Notes 32 3. ES-2024 settings 3.1 VALN Click Advanced Application and VLAN in navigation panel to display the configurat
IES-5000/5005/6000 Support Notes 33 Create a VLAN with VID of 20. Assign ports 2 and 10 to be members of VLAN20. Select the Tx Tagging option t
IES-5000/5005/6000 Support Notes 343.2 PVID setup Click Advanced Application and VLAN in navigation panel to display the configuration screen as s
IES-5000/5005/6000 Support Notes 35 After the configuration on the devices are complete, video traffic will go through the 0/33 channel and the da
IES-5000/5005/6000 Support Notes 36VDSL2 to ADSL2+ Fallback The VLC1348G-51 can automatically use ADSL2+ for connections where VDSL2 training fai
IES-5000/5005/6000 Support Notes 37Configure the P-660H-61 1. Telnet into the P-660H-61 a. In Windows, click Start (usually in the bottom left
IES-5000/5005/6000 Support Notes 382. General Setup a. Enter 1 in the Main Menu to open Menu 1 – General Setup. b. Type a name in the System Na
IES-5000/5005/6000 Support Notes 3Triple Play scenario topology All contents copyright (c) 2008 ZyXEL Communications Corporation.
IES-5000/5005/6000 Support Notes 393. Remote Node Setup a. Enter 11 in the Main Menu to open Menu 11 – Remote Node Setup. b. Enter 1 to configu
IES-5000/5005/6000 Support Notes 40c. Menu 11.1 – Remote Node Profile appears. d. Select Yes in the Active field. e. Select RFC 1483 in the En
IES-5000/5005/6000 Support Notes 41j. Menu 11.6 – Remote Node ATM Layer Options appears. k. Specify VPI and VCI. In this case, we type 8 in the
IES-5000/5005/6000 Support Notes 42Configure the VLC1348G-51 1. Login a. Connect to the IES-5000 via Internet browser. 192.168.1.1 is the defau
IES-5000/5005/6000 Support Notes 43 All contents copyright (c) 2008 ZyXEL Communications Corporation.
IES-5000/5005/6000 Support Notes 442. VDSL Port Setup a. Click Port > VDSL. b. Select slot 3 and port 1, and click Load to display the setti
IES-5000/5005/6000 Support Notes 453. PVC Setup a. Click Port > PVC. b. Select slot 3 and port 1, and click Load to display the settings as s
IES-5000/5005/6000 Support Notes 464. Config save a. Click Config Save on the navigation panel. b. Click the Save button to save your configura
IES-5000/5005/6000 Support Notes 475. Check status a. Click Statistics > Port Statistics. b. Click ID 3 to display the Counter screen. Protoc
IES-5000/5005/6000 Support Notes 48 All contents copyright (c) 2008 ZyXEL Communications Corporation.
IES-5000/5005/6000 Support Notes 4Hardware connections: P-870H-51 1. DSL: Connect the DSL jack to the VLC1348G-51 card on IES-5000. 2. Ether
IES-5000/5005/6000 Support Notes 49Impulse Noise Protection (INP) The impulse noise generator is required to prove the burst noise immunity of th
IES-5000/5005/6000 Support Notes 50Upstream Power Back-Off (UPBO) What is UPBO? Upstream Power back-of (UPBO) helps to run services over loops w
IES-5000/5005/6000 Support Notes 51The followings are general conclusions for applying UPBO in real network. • Non-FEXT dominated environment:
IES-5000/5005/6000 Support Notes 523. Improved performance of short loops The goal of this mode is to maximize the performance of short loops kee
IES-5000/5005/6000 Support Notes 53802.1ag CFM What is CFM? IEEE 802.1ag Connectivity Fault Management (CFM) allows service providers to manage
IES-5000/5005/6000 Support Notes 54Often there are three different organizations involved in a Metro Ethernet service: customers, service provider
IES-5000/5005/6000 Support Notes 55LBM—Loop Back Message LTM—Link Trace Message • MIP--Maintenance Intermediate Point o An MIP port forwards t
IES-5000/5005/6000 Support Notes 56WEB GUI Introduction 1. CFM MD Screen CFM Enable: Select or deselect the check box and click Apply to turn
IES-5000/5005/6000 Support Notes 572. CFM MA Screen MA Name: Type a name (up to 15 printable ACSII characters) for this MA. This is for identi
IES-5000/5005/6000 Support Notes 583. CFM MEP Screen Endpoint ID: Select a valid MEP ID which is defined in the CFM maintenance association sc
IES-5000/5005/6000 Support Notes 5Firmware versions: ES-2024A V3.80(TX.0)C0 IES-5000 MSC1000G: V3.90(LU.1)C0 VLC1348G-51: V3.90(BHB.0)b1 P-
IES-5000/5005/6000 Support Notes 594. Loopback Diagnosis MD:Select an MD name. MA: Select an MA name under the selected MD. MEPID: Select an ME
IES-5000/5005/6000 Support Notes 60CLI Command Introduction • Enable CFM MSC1000G> switch cfm enable • Disable CFM MSC1000G>swtich
IES-5000/5005/6000 Support Notes 61MSC1000G> diagnostic cfmlinktrace set <md-name><ma-name><ep-id><remote-ep-id>|<ma
IES-5000/5005/6000 Support Notes 62Setting up different DSL port speeds to different subscribers An ISP may want to configure a different line sp
IES-5000/5005/6000 Support Notes 63 Similarly, configure a profile to allow a high line speed. Enter a descriptive name for the profile (for examp
IES-5000/5005/6000 Support Notes 642.1 Menu 1: General Setup Go to Menu 1 to set the Prestige 660R-61 in bridge mode. In this menu, select No in t
IES-5000/5005/6000 Support Notes 65 2.4 Menu11.6: Remote Node ATM Layer Options Make sure the VPI and VCI settings are the same as on the IES-5000
IES-5000/5005/6000 Support Notes 66Configuring 802.1Q VLAN A VLAN (Virtual Area Network) allows a physical network to be partitioned into multipl
IES-5000/5005/6000 Support Notes 67on the IES-5000, another VLAN (to which the two ports are a member of) need to be configured. 1. IES-5000 Sett
IES-5000/5005/6000 Support Notes 68 For this example, assign VLAN 200(PVID) to ENET1 and ENET2. Also, assign VLAN 10 and VLAN 20 to Port1 and port
IES-5000/5005/6000 Support Notes 6Configure the P-870H-51: In this scenario, we will use the CPE P-870H-51 with factory-default setting. How to
IES-5000/5005/6000 Support Notes 69Station/ Application server Authentication Server (RADIUS) AuthorizedUnauthorized X SHDSL/ADSL modem SHDSL/ADS
IES-5000/5005/6000 Support Notes 70 2. RADIUS Setup: Vantage 50 You can use any RADIUS server (such as Funk Steel-Belted RADIUS, Cisco Access Con
IES-5000/5005/6000 Support Notes 71 3. Supplicant Setup: Windows XP You can use any supplicant/client software (such as MeetingHouse Aegis clien
IES-5000/5005/6000 Support Notes 72 Click on the message balloon to display the login screen where you can enter your account user name and
IES-5000/5005/6000 Support Notes All contents copyright (c) 2008 ZyXEL Communications Corporation. 73 Once you are authenticated successfully, y
IES-5000/5005/6000 Support Notes ADSL/SHDSL modem Syslog server Uplink Network IES-5000 ALC-1248G SLC-1248G Setting up a Syslog server In this se
IES-5000/5005/6000 Support Notes 75After the installation process is complete, start the daemon from the Start menu. A screen displays as shown. I
IES-5000/5005/6000 Support Notes All contents copyright (c) 2008 ZyXEL Communications Corporation. Ring Topology Application 76A ring topolo
IES-5000/5005/6000 Support Notes 77ports 1 and 2. The following shows the CLI commands. CI command: TGE1> sys sw rstp enable TGE1> sys s
IES-5000/5005/6000 Support Notes 78 Click Uplink2 to configure this port. Select Rapid Spanning Tree Protocol to enable it on the port. All co
IES-5000/5005/6000 Support Notes 7Configure the IES-5000 1. System login. a. Connect to the IES-5000 via Internet browser. 192.168.1.1 is the
IES-5000/5005/6000 Support Notes 79 Follow the same procedure to activate STP on uplink port 1. The following figure shows an example. All conte
IES-5000/5005/6000 Support Notes 80 3. ES-4024 Settings 3.1 Activating Spanning Tree protocol This section shows you how to enable STP on the s
IES-5000/5005/6000 Support Notes 81ports 1 and 2. 4. Status Results After you connect the uplink port 1 on IES-2000 to port 2 on the ES-4024,
IES-5000/5005/6000 Support Notes 82 IGMP Snooping/IGMP Filtering Application Without IGMP snooping, multicast traffic is treated in the same ma
IES-5000/5005/6000 Support Notes 83Setting up IGMP snooping/IGMP filtering In this section, we will show you how to configure IGMP snooping and fi
IES-5000/5005/6000 Support Notes 84 Limiting Internet access to users on specific DSL ports Some ISPs may want to limit the number of computers
IES-5000/5005/6000 Support Notes 85will not be able to access the Internet on port 3. Save the settings to make the changes take effect. CI com
IES-5000/5005/6000 Support Notes DHCP Server Network IES-5000(ALC/SLC) ADSL/SHDSL CPE DHCP ClientPort 25 Setting up DHCP Relay Option 82 ow
IES-5000/5005/6000 Support Notes 87 2. CPE settings evice to DSL port 25. Refer to the previous sections on how to . IP Commander settings creen
IES-5000/5005/6000 Support Notes 88 Enter the login user name and password. The default user name is “administrator” and the password is “incognit
IES-5000/5005/6000 Support Notes 82. Configure the VLC1348G-51. a. Click Port > VDSL. b. Choose slot 3 and port 1, and click Load to open
IES-5000/5005/6000 Support Notes 89A screen displays as shown. Make sure that the status of your DHCP is online. Then click Wizards > Rule Wiza
IES-5000/5005/6000 Support Notes 90 Assign one or a range of IP addresses for this rule. For this example, set the client IP pool in the 192.168.1
IES-5000/5005/6000 Support Notes 91Select DHCP Option in the Keywords field. A configuration screen displays. Set the fields in the screen as sho
IES-5000/5005/6000 Support Notes 92 After you have finished the rule wizard settings, the following screen displays. Click Next to continue. Al
IES-5000/5005/6000 Support Notes 93In the next wizard screen, click Next to continue. In next screen, you may specify a DHCP template (with the
IES-5000/5005/6000 Support Notes 94 For this template, we enter “192.168.1.1” as the gateway IP address for the DHCP client. All contents copyrig
IES-5000/5005/6000 Support Notes 95In the next screen, you may choose whether to apply automatic DDNS service on the DHCP server or not. Click Fi
IES-5000/5005/6000 Support Notes 96 After the configuration, your computer should obtain an IP address of 192.168.1.201 from the DHCP server once
IES-5000/5005/6000 Support Notes All contents copyright (c) 2008 ZyXEL Communications Corporation. 97 Setting up Packet Filtering u how to c
IES-5000/5005/6000 Support Notes 98 7- 4 accept-all 7- 5 accept-all 7- 6 accept-all 7- 7 accept-all 7- 8 accept-all 7- 9 accept-all 7-